Posted on

Case Study: Repairing 270-Metre Wastewater Pipe Bridge Spanning Fields and Waterways

A 270 metre section of pipe bridge carrying wastewater to a treatment plant undergoes repair and strengthening with SylWrap CR Corrosion Protection Wrap
Share this post

Bethell Construction and Sylmasta provide pipe bridge strengthening to avoid repair clamps causing a collapse

A 270-metre section of pipe bridge on steel supports carrying wastewater over fields and waterways undergoes strengthening with specialist SylWrap Pipe Repair Bandages after the structure became too weak to repair with clamps.

Case Study Data


Site
Wastewater treatment plant
Location
United Kingdom
Repair Type
Pipe bridge repair and strengthening
Defect
270-metre section of pipe bridge leaking and heading towards potential collapse

Products Used


SylWrap CR Corrosion Protection Wrap
Composite pipe repair bandage incorporated with corrosion inhibitors to strengthen and repair pipework in harsh environments

Pipe Bridge Strengthening Case Study Details


The 525mm diameter pipe sat on steel supports to carry sewage and wastewater across fields and waterways to a treatment plant in the north of England.

Numerous leaks had appeared in the pipe over many years. Heavy, metal clamps addressed each of these breaches. However, the pipe had now reached the stage where it was unwise to add any more weight to the weakened structure for fear it might collapse.



Sylmasta client Bethell Construction were approached by the water company responsible for the treatment plant. They asked Bethell to repair and strengthen the pipe with an alternative method to clamps.

Bethell benefits from SylWrap LH Resin

It became clear the best solution would be to carefully remove all previously applied clamps and clad the entire pipe bridge with SylWrap Pipe Repair Bandage.



Because Sylmasta manufacture SylWrap at our world-leading composite pipe repair production facility in the United Kingdom, we were able to produce a customised SylWrap CR Corrosion Protection Wrap for Bethell.

It contained highly effective corrosion inhibitors to offer greater protection to the pipe bridge against substrate corrosion. The bandage was also coloured black, giving it a smart look once applied to the pipe.

The biggest consideration came with the resin. Since August 2023, EU and UK REACH legislation stipulates that industrial users can only handle products containing greater than 0.1% free diisocyanate after undergoing extensive health and safety training.

These laws have led Sylmasta to formulate a new low hazard resin below 0.1%. SylWrap Pipe Repair Bandages made with this LH resin are the only moisture cured wraps currently on the market which are free from the regulations.

Supplying Bethell with SylWrap CR containing LH resin meant their workforce did not need to undertake safety training before starting the repair. This saved time, financial outlay on training costs and offered reduced risk to the team.

Leak sealing and pipe bridge strengthening with SylWrap CR

Scaffolding was erected to access the pipe bridge. Removing the clamps revealed a pipe in even worse condition than first thought. One subsequent storm after clamp removal sent wastewater cascading from the pipe as it struggled to cope with rainwater runoff, increasing the urgency of the repair.



The pipe was wrapped in a minimum of six layers of SylWrap CR. Where the condition of the pipe was worse such as at significant leak points, application extended up to 10 layers.

This created a 6mm to 10mm thick shell around the brittle metalwork, restoring the integrity of the pipe and increasing bend strength. With the pipe bridge gravity fed, SylWrap CR also easily contained all leaks.



In some places, removal of the rubber layer from the clamps would cause even more damage. Bethell therefore left the rubber in situ and overwrapped with SylWrap CR.

Wrapping of the pipe bridge took place in two stages. The first stage covered 140 metres using 570 SylWrap CR Bandages. The second stage covers the remaining 130 metres and will leave the pipe wrapped in almost 1,000 SylWrap CR.



A significant cost saving for the water company

The only alternative to strengthening the pipe bridge with SylWrap CR was total replacement. This would have involved diverting wastewater, dismantling the structure and safe disposal. Followed by fabrication, installation and connection of a new pipe bridge.

Bethell and Sylmasta therefore saved the water company from undertaking a complex, long and expensive project. The water company are now looking at other similar degraded pipe bridges on their network which can also undergo repair and refurbishment with SylWrap.

Please contact Sylmasta if you need help with pipe bridge repairs and strengthening

Call: +44 (0)1444 831 459
Email: sales@sylmasta.com


Share this post